TH-GC Series Layer2 Manajan Ethernet Canja 4xGigabit Combo(RJ45/SFP) 16×10/100/1000Base-T PoE/24×10/100/1000Base-T PoE
Gigabit Layer 2 Sarrafa PoE Switch shine Canjawar PoE mai Ajiye Makamashi mai zaman kansa. Tare da babban inganci da babban saurin hanyar sadarwa na IC da mafi kwanciyar hankali PoE Chip, tashoshin PoE sun hadu da IEEE802.3af 15.4w da IEEE802.3at 30w. Wannan samfurin zai iya samar da haɗin kai maras kyau don 10/ 100/1000M Ethernet, kuma tashar wutar lantarki na PoE na iya ganowa ta atomatik da kuma sarrafa na'urorin da aka yi amfani da su da suka dace da IEEE802.3af / a daidaitattun. Na'urorin Non-PoE suna da ƙarfi da ƙarfi kuma suna watsa bayanai kawai.
● Canja wurin bayanai don kyamarori masu sa ido na cibiyar sadarwa
● Taimakawa IEEE802.3/ IEEE802.3i/IEEE802.3uIEEE802.3ab/IEEE802.3z, IEEE802.3af/at, store-and-gaba
● Mai dacewa da IEEE802.3at (30W) da IEEE802.3af (15.4w)
● tashar tashar Ethernet tana goyan bayan 10 / 100 / 1000M daidaitawa da ayyukan PoE
● Alamar kwamitin kula da matsayi da kuma taimakawa binciken gazawar
● Taimakawa 802.1x tashar tashar jiragen ruwa, goyan bayan tabbatar da AAA, goyan bayan TACACS + tabbatarwa; Saitunan tsaro na DOS, saitunan ACL
● Taimakawa WEB, TELNET, CLI, SSH, SNMP, Gudanar da RMON
● Taimakawa PoE Power Management da PoE Watchdog
● Ƙarfafa Kariyar Walƙiya: Yanayin Gabaɗaya 4KV, Yanayin Bambanci 2KV, ESD 15KV
P/N | Bayani |
Saukewa: TH-GC0416PM2-Z200W | Layer2 Manajan Ethernet Canja 4x1Gigabit Combo(RJ45/SFP)16 × 10/ 100/ 1000Base-T Poe Port, Ƙarfin Ƙarfin Ciki 52V/3.8A, 200w |
Saukewa: TH-GC0416PM2-Z300W | Layer2 Manajan Ethernet Canja 4x1Gigabit Combo(RJ45/SFP)16 × 10/ 100/ 1000Base-T Poe Port, Ƙarfin Ƙarfin Ciki 52V/5.76A, 300w |
Saukewa: TH-GC0424PM2-Z300W | Layer2 Managed Ethernet Switch 4xGigabit Combo(RJ45/SFP)24×10/100/1000Base-T PoE Port, Internal Power Supply 52V/5.76A, 300w |
Saukewa: TH-GC0424PM2-Z400W | Layer2 Managed Ethernet Switch 4xGigabit Combo(RJ45/SFP)24×10/100/1000Base-T PoE Port, Internal Power Supply 52V/7.69A, 400w |
Interface I/O | ||
Shigar da Wuta | Shigar da AC 110-240V, 50/60Hz | |
Kafaffen Port | P/N | Kafaffen Port |
Saukewa: TH-GC0416PM2-Z200w | 16 x 10/100/1000Mbps PoE Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
Saukewa: TH-GC0416PM2-Z300w | 16 x 10/100/1000Mbps PoE Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
Saukewa: TH-GC0424PM2-Z300w | 24 x 10/100/1000Mbps PoE Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
Saukewa: TH-GC0424PM2-Z400w | 24 x 10/100/1000Mbps Poe Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
Ayyuka | ||
Ƙarfin Canjawa | 56Gbps | |
Kayan aiki | 41.66Mpps | |
Fakitin Buffer | 4 Mb | |
Flash Memory | 16MB | |
DDR SDRAM | 128MB | |
MAC Address | 8K | |
Jumbo Frame | 9.6kbytes | |
VLANs | 4096 | |
Yanayin Canja wurin | Ajiye da gaba | |
Farashin MTBF | 100000 hours | |
Daidaitawa | ||
Ka'idar hanyar sadarwa | IEEE 802.3: Ethernet MAC Protocol | |
IEEE 802.3i: 10BASE-T Ethernet | ||
IEEE 802.3u: 100BASE-TX Fast Ethernet | ||
IEEE 802.3ab: 1000BASE-T Gigabit Ethernet | ||
IEEE 802.3z: 1000BASE-X Gigabit Ethernet (fiber na gani) | ||
IEEE 802.3az: Ƙarfin Ƙarfafa Ƙarfafawa | ||
IEEE 802.3ad: Daidaitaccen Hanyar yin haɗin haɗin haɗin gwiwa | ||
IEEE 802.3x: Gudanar da gudana | ||
IEEE 802.1ab: LLDP/LLDP-MED (Link Layer Discovery Protocol) | ||
IEEE 802.1p: LAN Layer QoS/CoS Protocol Traffic Prioritization (Multicast) | ||
aikin tacewa) | ||
IEEE 802.1q: Aikin Gadar VLAN | ||
IEEE 802.1x: Abokin Ciniki/Sarrafa Sabar da Ka'idar Tabbatarwa | ||
IEEE 802.1d: STP; IEEE 802.1s: MSTP; IEEE 802.1w: RSTP | ||
PoE Protocol | IEEE802.3af (15.4W); IEEE 802.3at (30W) | |
Matsayin Masana'antu | EMI: FCC Sashe na 15 CISPR (EN55032) aji A | |
EMS: EN61000-4-2 (ESD), EN61000-4-4 (EFT), EN61000-4-5 | ||
Saukewa: IEC60068-2-27 | ||
Faɗuwar kyauta: IEC 60068-2-32 | ||
Saukewa: IEC 60068-2-6 | ||
Matsakaicin hanyar sadarwa | 10Base-T: Cat3, 4, 5 ko sama da UTP(≤100m) | |
100Base-TX: Cat5 ko sama da UTP(≤100m) | ||
1000Base-TX: Cat5 ko sama da UTP(≤100m) Na gani | ||
Multimode fiber: 1310nm, 2km | ||
Fiber yanayin guda ɗaya: 1310nm, 20/40 km; 1550nm, 60/80/100/120Km | ||
Kariya | ||
Takaddun Tsaro | CE/FCC/RoHS | |
Muhalli | ||
Muhallin Aiki | Zazzabi Aiki: -20 ~ 55 ° C | |
Adana Zazzabi: -40 ~ 85°C | ||
Humidity na aiki: 10% ~ 90%,mara tari | ||
Ajiya Zazzabi: 5% ~ 90%,mara tari | ||
Tsawon Aiki: Matsakaicin ƙafa 10,000 | ||
Tsayin ajiya: Matsakaicin ƙafa 10,000 | ||
Nuni | ||
LED Manuniya | PWR (watar wuta) | |
SYS (Tsarin) | ||
1-24 PoE & ACT (PoE) | ||
1-24 Link & ACT (Haɗi & Dokar) | ||
25-28 Haɗi (Haɗi) | ||
Dokar 25-28 (Dokar) | ||
Canjin DIP | Sake saiti | |
Makanikai | ||
Girman Tsarin | Girman Samfura (L*W*H): 440* 284*44mm | |
Girman Kunshin (L*W*H): 495*350*103mm | ||
nauyi: 3.5kg | ||
GW: 4.25kg | ||
Bayanin tattarawa | Karton MEAS: 592*510*375mm | |
Shirya Qty: 5 raka'a | ||
Nauyin shiryawa: 22.5KG | ||
Layer 2 Ayyukan Software | ||
Gudanar da tashar jiragen ruwa | Kunna/A kashe Port | |
Speed, Duplex, MTU Saitin | ||
Ikon sarrafawa | ||
Duba bayanan tashar jiragen ruwa | ||
Port Mirroring | Yana goyan bayan madubin tashar tashar jiragen ruwa biyu | |
Iyakar Gudun Port | Yana goyan bayan gudanarwar shigar da tushen tashar tashar ruwa / fitarwa | |
Keɓewar tashar jiragen ruwa | Goyi bayan keɓewar tashar jiragen ruwa ta ƙasa, kuma za ta iya sadarwa tare da tashar tashar sama | |
Damuwar guguwa | Yana goyan bayan unicast wanda ba a san shi ba, multicast, multicast wanda ba a san shi ba, nau'in watsa shirye-shirye na kashe guguwa | |
Ƙunƙarar guguwa bisa ƙa'idar bandwidth da tace guguwa | ||
Haɗin haɗin gwiwa | Goyi bayan tarawar hannu a tsaye | |
Goyi bayan tara kuzarin LACP | ||
VLAN | Shiga | |
Jiki | ||
Matasa | ||
Taimako tashar jiragen ruwa, yarjejeniya, MAC na tushen VLAN partitioning | ||
Goyan bayan GVRP mai ƙarfi VLAN rajista | ||
Muryar VLAN | ||
MAC | Goyan bayan ƙari, sharewa | |
Iyakar karatun adireshin MAC | ||
Goyi bayan saitin lokacin tsufa mai ƙarfi | ||
Yakin itace | Goyi bayan ka'idar itace ta STP | |
Yana goyan bayan RSTP Rapid Spanning Tree Protocol | ||
Yana goyan bayan MSTP Protocol na Bishiyoyi da sauri | ||
Multicast | Goyan bayan ƙari, sharewa | |
IGMP-snooping | ||
Taimakawa MLD-Snooping | ||
Taimako v1/2/3 mai tsauri mai duba multicast | ||
DDM | Taimakawa SFP/SFP+DDM | |
Extended Aiki | ||
ACL | Dangane da tushen MAC, MAC manufa, nau'in yarjejeniya, tushen IP, manufa | |
IP, L4 tashar jiragen ruwa | ||
QoS | Dangane da rarrabuwa 802.1p (COS). | |
Dangane da rarrabawar DSCP | ||
Rarraba bisa tushen IP, IP mai zuwa, da lambar tashar jiragen ruwa | ||
Taimakawa SP, dabarun tsara tsarin WRR | ||
Goyan bayan ƙimar ƙimar ƙimar CAR | ||
LLDP | Goyi bayan ka'idar gano hanyar haɗin gwiwa ta LLDP | |
Saitunan mai amfani | Ƙara/share masu amfani | |
Shiga | Shigar mai amfani, aiki, matsayi, abubuwan da suka faru | |
Anti hari | DOS tsaro | |
Goyon bayan kariyar CPU da iyakance adadin aika fakitin CPU | ||
ARP dauri (IP, MAC, PORT dauri) | ||
Takaddun shaida | Taimakawa 802.1x ingantaccen tashar jiragen ruwa | |
Goyi bayan takaddun shaida na AAA | ||
Ganewar hanyar sadarwa | Taimakawa ping, telnet, ganowa | |
Gudanar da Tsarin | Sake saitin na'ura, ajiyar sanyi/mayarwa, sarrafa haɓakawa, saitin lokaci, da sauransu. | |
Ayyukan gudanarwa | ||
CLI | Goyi bayan sarrafa layin umarni na tashar tashar jiragen ruwa | |
SSH | Goyi bayan sarrafa nesa na SSHv1/2 | |
TELNET | Goyi bayan sarrafa nesa na telnet | |
WEB | Goyan bayan saitunan Layer 2, Layer 2 da Layer 3 duba | |
SNMP | SNMP V1/V2/V3 | |
Taimakon tarko: ColdStart, WarmStart, LinkDown, LinkUp | ||
RMON | Taimakawa RMON v1 | |
PoE | Goyan bayan wutar lantarki na PoE | |
Sauran ayyuka | Goyan bayan DHCP Snooping, Option82, DHCP Server | |
Goyi bayan gano ARP mai tsauri | ||
Taimakawa takaddun shaida TACACS+ | ||
Goyan bayan takaddun shaida na DNS | ||
Goyan bayan saitunan tsaro na tashar jiragen ruwa | ||
Goyan bayan ka'idar MVR | ||
Goyan bayan aikin gano na USB VCT | ||
Goyan bayan UDLD yarjejeniya |